his is the last of the three articles devoted to the topic of a Smith Chart. The previous two articles, [1,2], introduced the concept of normalized load impedance leading to the resistance and reactance circles, which in turn were used to locate the normalized load impedance on the Smith Chart. This article explains how to use a Smith Chart to determine the input impedance to transmission line at a given distance from the source or the load.
Recall the two typical circuit models of a transmission line [1]. In Model 1, shown in Figure 1, the source is located at z = 0, and the load is located at z = L.
In Model 2, shown in Figure 2, the load is located at d = 0, and the source is located at d = L.
where (d) is the voltage reflection coefficient at any location d, away from the load, and can be expressed in terms of the load reflection coefficient as
Utilizing Eq. (3) in Eq. (2), we obtain
On the Smith Chart, obtaining (d) from L means keeping the magnitude, ΓL, constant and decreasing the phase by 2βd. Phase decrease corresponds to the clockwise rotation on the Smith Chart. This is shown in Figure 3.
Let’s return to Eq. (1). Dividing both sides by the characteristic impedance of the line, ZC , we obtain the normalized input impedance to the line at any location d away from the load,
or
The mathematical form of these two equations is the same! If L is replaced by (d) then L gets replaced by in(d).
When using Smith Chart, the distance d is expressed in terms of wavelengths. A complete rotation around the Smith Chart corresponds to a phase change of 360° or 2π radians.
The phase constant β is related to the wavelength λ by
from which
We have shown how to obtain in(d), the normalized input impedance to the line at a distance d away from the load. What about in(z), the normalized input impedance to the line at a distance z away from the source?
in(z) can be easily obtained from in(d) since the two distance variables are related by [3,4],
In summary, to determine the input impedance to the line at any distance from the load or the source, using Smith Chart, the following steps need to be taken:
2. Obtain the normalized load impedance
3. Locate this impedance on the Smith Chart at the intersection of the resistance and reactance circles.
5. To obtain the normalized input impedance to the line at a distance d from the load, move clockwise on the constant radius circle from L.
6. Multiply the normalized input impedance by the characteristic impedance of the line, ZC, to obtain the actual input impedance.
References
- Adamczyk, B., “Smith Chart and Input Impedance to Transmission Line – Part 1: Basic Concepts,” In Compliance Magazine, April 2023.
- Adamczyk, B., “Smith Chart and Input Impedance to Transmission Line – Part 2: Resistance and Reactance Circles,” In Compliance Magazine, May 2023.
- Adamczyk, B., “Sinusoidal Steady State Analysis of Transmission Lines – Part II: Voltage, Current, and Input Impedance Calculations – Circuit Model 1,” In Compliance Magazine, February 2023.
- Adamczyk, B., “Sinusoidal Steady State Analysis of Transmission Lines – Part III: Voltage, Current, and Input Impedance Calculations – Circuit Model 2,” In Compliance Magazine, March 2023.